Registry JSON CSV exports
Theme

Choose how MSRBot.io looks on this device.

Preference is stored in this browser only.

The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55
[ACTIVE]

Practical use and calculation of CCT and Duv

Metadata

Publisher
Illuminating Engineering Society
Doc Type
Technical Journal
Abstract
Correlated color temperature (CCT) is often used to represent chromaticity of white light sources, but chromaticity is two-dimensional, and another dimension, the distance from the Planckian locus, is often missing. Duv is defined in ANSI C78.377 for this purpose but is not yet widely used. In this article, the use of a combination of CCT and Duv is proposed as an intuitive expression of chromaticity of white light sources for general lighting. In addition, this article presents practical calculation methods to calculate CCT and Duv, having sufficient accuracy, within an error of 1 K, in a wide range of chromaticity, from 1000 to 20,000 K in CCT and −0.03 to 0.03 in Duv.
Publication Date
2000-08-01
DOI
10.1080/15502724.2014.839020
Link
https://doi.org/10.1080/15502724.2014.839020
Author(s)
Yoshi Ohno

Reference Tree

Explore all references and references to this document, as a navigable tree.

Open Reference Tree
Reference this Doc

Plain text (ISO 690 compliant)

Preview:
Yoshi Ohno; Practical use and calculation of CCT and Duv, The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55; Illuminating Engineering Society, 2000. Available at https://doi.org/10.1080/15502724.2014.839020
Snippet:
Yoshi Ohno; Practical use and calculation of CCT and Duv, The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55; Illuminating Engineering Society, 2000. Available at https://doi.org/10.1080/15502724.2014.839020

HTML (ISO 690 compliant)

Preview:
Yoshi Ohno; Practical use and calculation of CCT and Duv, The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55; Illuminating Engineering Society, 2000. Available at https://doi.org/10.1080/15502724.2014.839020
Snippet:
<span class="citation">Yoshi Ohno; <cite>Practical use and calculation of CCT and Duv</cite>, The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55; Illuminating Engineering Society, 2000. Available at <a href="https://doi.org/10.1080/15502724.2014.839020" target="_blank" rel="noopener">https://doi.org/10.1080/15502724.2014.839020</a></span>

SMPTE Icon SMPTE's HTML Pub

Preview:
Yoshi Ohno; Practical use and calculation of CCT and Duv, The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55; Illuminating Engineering Society, 2000
doi: 10.1080/15502724.2014.839020
url: https://doi.org/10.1080/15502724.2014.839020
Snippet:
<li>
Yoshi Ohno; <cite id="bib-issn-15502716">Practical use and calculation of CCT and Duv</cite>, The Journal of the Illuminating Engineering Society Volume 10, 2014 - Issue 1, Pages 47-55; Illuminating Engineering Society, 2000
<span class="doi">10.1080/15502724.2014.839020</span>
</li>

Referenced By