A New Photometer for Measuring Screen Brightness
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Abbreviated Title
- J SMPTE
- Volume
- 83, No. 9, pp. 737–741
- Abstract
- A new photometer has been designed for the measurement of screen brightness and other photometric parameters relating to projection quality. The photometer is a compact, handheld spot meter with see-through optics and an internal meter visible in the viewfinder. The photometer features a silicon photovoltaic cell and solid-state operational amplifiers for maximum accuracy, stability and repeatability, and a computer-designed glass filter for optimal matching to the spectral response of the human eye. The design, testing and application of the new photometer is described.
- Publication Date
- 1974-09-01
- DOI
10.5594/J06928- ISSN
- Print:
0361-4573 - Link
- https://doi.org/10.5594/J06928
- Author(s)
- Richard A. WalkerPhoto Research, Div. of Kollmorgen Corp., 3000 North Hollywood Way, Burbank, CA 91505James K. BranchPhoto Research, Div. of Kollmorgen Corp., 3000 North Hollywood Way, Burbank, CA 91505
- Copyright
- © 1974 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- A Survey of Classroom Projection Conditions [Active]
- Measured and Observed Discrepancies of Screen Luminances [Active]
- A New Photometer for Control of Color Printers [Active]
- 1. Klocpfel Don V. , Ed., Motion Picture Projection and Theatre Presentation Manual , SMPTE , 1969 . EXTERNAL
- 10. Walker R. A. , “Optical systems for defining the viewing and measuring field in luminance/radiance meters,” Appl. Opt. , 11 : 2060 , Sept. 1972 . EXTERNAL
- 11. Crandell F. F. Freund K. , “New photoelectric brightness spot meter,” Jour. SMPTE , 61 : 215 – 222 , Aug. 1953 . EXTERNAL
- 12. Lyells L. C. , The Camera Craftsman , 19 : 5 , No. 6 , Nov./Dec. 1973 . EXTERNAL
- 14. Witherell P. G. Faulhaber M. E. , “The silicon cell as a photometric detector,” Appl. Opt. , 9 : 73 , 1970 . EXTERNAL
- 15. Danahy E. L. , “The real world of silicon photodiodes,” Electro-Optical Systems Design , 2 : 36 , No. 5 , 1970 . EXTERNAL
- 16. Wendland P. H. , “Silicon photodiodes come into their own,” Optical Spectra , 7 : 33 , No. 10 , Oct. 1973 . EXTERNAL
- 18. Wright H. Sanders C. L. Gignac D. , “Design of glass filter combinations for photometers.” Appl. Opt. , 8 : 2449 , 1969 . EXTERNAL
- 2. Clark L. D. , “Picture quality of motion pictures as a function of screen luminance,” Jour. SMPTE , 61 : 241 – 247 , Aug. 1953 . EXTERNAL
- 3. Armbruster L. A. Stolle W. F. , “Optimum screen brightness for viewing 16mm Kodachrome prints,” Jour. SMPTE , 61 : 248 – 256 , Aug. 1953 . EXTERNAL
- 4. Estcs R. L. , “Effects of stray light on the quality of projected pictures at various levels of screen brightness,” Jour. SMPTE , 61 : 257 – 272 , Aug. 1953 . EXTERNAL
- 5. Bartleson C. J. , “Interrelations among screen luminance, camera exposure and quality of projected color transparencies,” Photo. Sci & Eng. , 9 : 174 , May/June 1965 . EXTERNAL
- 6. Kodak Eastman , Audiovisual Projection , Kodak Pamphlet #S-3, Eastman Kodak Co. , Rochester, N.Y. , 1973 . EXTERNAL
- 8. Crandell Frank F. , “Measuring projection screen brightness,” Preprint #103–24, presented at the 103rd SMPTE Conference in Los Angeles 7 May 1968 . EXTERNAL
- 9. Klocpfel Don V. , op cit, pp. 23 – 24 . EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J06928.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
Richard A. Walker and James K. Branch; A New Photometer for Measuring Screen Brightness, Journal of the SMPTE ( Volume: 83, Issue: 9, September 1974); SMPTE, 1974. Available at https://doi.org/10.5594/J06928
Snippet:
Richard A. Walker and James K. Branch; A New Photometer for Measuring Screen Brightness, Journal of the SMPTE ( Volume: 83, Issue: 9, September 1974); SMPTE, 1974. Available at https://doi.org/10.5594/J06928
HTML (ISO 690 compliant)
Preview:
Richard A. Walker and James K. Branch; A New Photometer for Measuring Screen Brightness, Journal of the SMPTE ( Volume: 83, Issue: 9, September 1974); SMPTE, 1974. Available at https://doi.org/10.5594/J06928
Snippet:
<span class="citation">Richard A. Walker and James K. Branch; <cite>A New Photometer for Measuring Screen Brightness</cite>, Journal of the SMPTE ( Volume: 83, Issue: 9, September 1974); SMPTE, 1974. Available at <a href="https://doi.org/10.5594/J06928" target="_blank" rel="noopener">https://doi.org/10.5594/J06928</a></span>
SMPTE's HTML Pub
Preview:
Richard A. Walker and James K. Branch; A New Photometer for Measuring Screen Brightness, Journal of the SMPTE ( Volume: 83, Issue: 9, September 1974); SMPTE, 1974
doi: 10.5594/J06928
url: https://doi.org/10.5594/J06928
doi: 10.5594/J06928
url: https://doi.org/10.5594/J06928
Snippet:
<li> Richard A. Walker and James K. Branch; <cite id="bib-10-5594-j06928">A New Photometer for Measuring Screen Brightness</cite>, Journal of the SMPTE ( Volume: 83, Issue: 9, September 1974); SMPTE, 1974 <span class="doi">10.5594/J06928</span> </li>
Referenced By
- A New Direct-Reading Three-Color Meter [Active]
- Progress Committee Report for 1974 [Active]