Transfer Function Measurements When the Reference Signal is Known but not Accessible
Metadata
- Publisher
- SMPTE — Hollywood, CA
- Doc Type
- Conference Paper
- Content Type
- Original Research
- Volume
- 00, pp. 1–7
- Abstract
- Transfer Function measurements offer significant benefits over historical band spectrum measurements for calibrating loudspeakers by additionally calculating phase and coherence in the frequency domain and identifying the arrival time of reflections in the time domain. More and more loudspeakers are being offered with manufacturer provided signal processing, including phase correction. Using a transfer function measurement during calibration can help ensure that any processing used to achieve the target frequency response does not accidentally counteract the phase correction integral to the speaker. But Transfer Function measurements require 2 channels: both the reference signal input to the speaker and a microphone in the sound field. Often in cinema systems it is difficult to duplicate the reference signal to an analyzer: there may be no spare inputs or outputs, limited routing options, and/or digital connections may be used between devices which are not conducive to a Y-cable. The present paper describes a method called Virtual Reference which provides a reference signal to an analyzer simply by virtue of having a recording of the reference signal which is to be played. The analyzer then can operate in its normal fashion - it does not need to know that its reference signal is coming from Virtual Reference. Virtual Reference can also detect, measure, and compensate for sample rate differences between the playback device and the analyzer. This way the analyzer can show a stable phase trace of the device while Virtual Reference separately displays a measurement of the clocking differences such as jitter and wander.
- Publication Date
- 2024-10-21
- DOI
10.5594/MOO/3049- ISBN
[object Object]- Link
- https://doi.org/10.5594/MOO/3049
- Author(s)
- Juan SierraSwapan GandhiJay WyattRoger Schwenke
- Keyword(s)
- Transfer Function, Reference Signal, Virtual Reference, Band Spectrum, Loudspeaker Calibration, Phase Correction, Sample Rate
- Copyright
- © 2024 SMPTE
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-MOO-3049.json
Reference this Doc
Plain text (ISO 690 compliant)
Preview:
Juan Sierra, Swapan Gandhi, Jay Wyatt, and Roger Schwenke; Transfer Function Measurements When the Reference Signal is Known but not Accessible, MTS 2024, Article 38 (pp. 1 to 7); SMPTE, 2024, ISBN: [object Object]. Available at https://doi.org/10.5594/MOO/3049
Snippet:
Juan Sierra, Swapan Gandhi, Jay Wyatt, and Roger Schwenke; Transfer Function Measurements When the Reference Signal is Known but not Accessible, MTS 2024, Article 38 (pp. 1 to 7); SMPTE, 2024, ISBN: [object Object]. Available at https://doi.org/10.5594/MOO/3049
HTML (ISO 690 compliant)
Preview:
Juan Sierra, Swapan Gandhi, Jay Wyatt, and Roger Schwenke; Transfer Function Measurements When the Reference Signal is Known but not Accessible, MTS 2024, Article 38 (pp. 1 to 7); SMPTE, 2024, ISBN: [object Object]. Available at https://doi.org/10.5594/MOO/3049
Snippet:
<span class="citation">Juan Sierra, Swapan Gandhi, Jay Wyatt, and Roger Schwenke; <cite>Transfer Function Measurements When the Reference Signal is Known but not Accessible</cite>, MTS 2024, Article 38 (pp. 1 to 7); SMPTE, 2024, ISBN: [object Object]. Available at <a href="https://doi.org/10.5594/MOO/3049" target="_blank" rel="noopener">https://doi.org/10.5594/MOO/3049</a></span>
SMPTE's HTML Pub
Preview:
Juan Sierra, Swapan Gandhi, Jay Wyatt, and Roger Schwenke; Transfer Function Measurements When the Reference Signal is Known but not Accessible, MTS 2024, Article 38 (pp. 1 to 7); SMPTE, 2024, ISBN: [object Object]
doi: 10.5594/MOO/3049
url: https://doi.org/10.5594/MOO/3049
doi: 10.5594/MOO/3049
url: https://doi.org/10.5594/MOO/3049
Snippet:
<li> Juan Sierra, Swapan Gandhi, Jay Wyatt, and Roger Schwenke; <cite id="bib-10-5594-moo-3049">Transfer Function Measurements When the Reference Signal is Known but not Accessible</cite>, MTS 2024, Article 38 (pp. 1 to 7); SMPTE, 2024, ISBN: [object Object] <span class="doi">10.5594/MOO/3049</span> </li>