Image-Converter Tube Camera with a Nanosecond Control System
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Abbreviated Title
- J SMPTE
- Volume
- 79, No. 1, pp. 34–35
- Abstract
- Image-Converter tubes such as the electron-optical transducers PIM-UMI<sup>1</sup> have a limiting time resolution of about 3 ps which is limited only by the time of establishing the electron image in the plane of the screen.<sup>2</sup> This time resolution was obtained in experiments with circular scanning of the image from miniature spark discharges.<sup>3</sup> However, circular scanning has not found broad application in the field of physical experimentation, and the method of linear scanning of a slit aperture is now used for studying high-speed processes. Maximum time resolution of electron-optical transducers is reached for a scanning time of 1 to 1.5 ns; pulses of such duration can be applied to the control plates of the electron-optical transducers, the resonance frequencies of which are about 250 to 350 MHz.
- Publication Date
- 1970-01-01
- DOI
10.5594/J16712- ISSN
- Print:
0361-4573 - Link
- https://doi.org/10.5594/J16712
- Author(s)
- V. V. KorobkinPhysical Institute of the Academy of Sciences USSR, MoscowM. Ya. ShchelevPhysical Institute of the Academy of Sciences USSR, Moscow
- Copyright
- © 1970 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- 1. Butslov M. M. , Uspekhi Nauchnoi Fotografii , 4 : 76 ( 1959 ). EXTERNAL
- 2. Zavoiskii E. K. Fanchenko S. D. , Applied Optics , 4 : No. 9 , 1155 ( 1965 ). EXTERNAL
- 3. Zavoiskii E. K. Fanchenko S. D. , Doklady AN SSSR 100 , 661 ( 1955 ). EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J16712.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
V. V. Korobkin and M. Ya. Shchelev; Image-Converter Tube Camera with a Nanosecond Control System, Journal of the SMPTE ( Volume: 79, Issue: 1, January 1970); SMPTE, 1970. Available at https://doi.org/10.5594/J16712
Snippet:
V. V. Korobkin and M. Ya. Shchelev; Image-Converter Tube Camera with a Nanosecond Control System, Journal of the SMPTE ( Volume: 79, Issue: 1, January 1970); SMPTE, 1970. Available at https://doi.org/10.5594/J16712
HTML (ISO 690 compliant)
Preview:
V. V. Korobkin and M. Ya. Shchelev; Image-Converter Tube Camera with a Nanosecond Control System, Journal of the SMPTE ( Volume: 79, Issue: 1, January 1970); SMPTE, 1970. Available at https://doi.org/10.5594/J16712
Snippet:
<span class="citation">V. V. Korobkin and M. Ya. Shchelev; <cite>Image-Converter Tube Camera with a Nanosecond Control System</cite>, Journal of the SMPTE ( Volume: 79, Issue: 1, January 1970); SMPTE, 1970. Available at <a href="https://doi.org/10.5594/J16712" target="_blank" rel="noopener">https://doi.org/10.5594/J16712</a></span>
SMPTE's HTML Pub
Preview:
V. V. Korobkin and M. Ya. Shchelev; Image-Converter Tube Camera with a Nanosecond Control System, Journal of the SMPTE ( Volume: 79, Issue: 1, January 1970); SMPTE, 1970
doi: 10.5594/J16712
url: https://doi.org/10.5594/J16712
doi: 10.5594/J16712
url: https://doi.org/10.5594/J16712
Snippet:
<li> V. V. Korobkin and M. Ya. Shchelev; <cite id="bib-10-5594-j16712">Image-Converter Tube Camera with a Nanosecond Control System</cite>, Journal of the SMPTE ( Volume: 79, Issue: 1, January 1970); SMPTE, 1970 <span class="doi">10.5594/J16712</span> </li>