Acceleration Accuracy: Analyses of High-Speed Camera Film
Metadata
- Publisher
- SMPTE
- Doc Type
- Journal Article
- Article Type
- research-article
- Abstract
- Acceleration due to gravity, g, was experimentally determined using the technique of micromotion analysis of high-speed motion-picture film taken of a steel sphere in free fall. Three methods of film analysis were compared with an independently calculated value of g. The analyses used and the error they produced were as follows: graphical, 6%; graphical-analytical, 1%; and analytical, 2%. For all of these experiments, a Bausch & Lomb Contour Measuring Projector was used
- Publication Date
- 1956-02-01
- DOI
10.5594/J14509- Link
- https://doi.org/10.5594/J14509
- Author(s)
- Derwyn Severy, Paul Barbour
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J14509.json
Reference this Doc
Plain text (ISO 690 compliant)
Preview:
Derwyn Severy and Paul Barbour; Acceleration Accuracy: Analyses of High-Speed Camera Film, Journal of the SMPTE ( Volume: 65, Issue: 2, February 1956); SMPTE, 1956. Available at https://doi.org/10.5594/J14509
Snippet:
Derwyn Severy and Paul Barbour; Acceleration Accuracy: Analyses of High-Speed Camera Film, Journal of the SMPTE ( Volume: 65, Issue: 2, February 1956); SMPTE, 1956. Available at https://doi.org/10.5594/J14509
HTML (ISO 690 compliant)
Preview:
Derwyn Severy and Paul Barbour; Acceleration Accuracy: Analyses of High-Speed Camera Film, Journal of the SMPTE ( Volume: 65, Issue: 2, February 1956); SMPTE, 1956. Available at https://doi.org/10.5594/J14509
Snippet:
<span class="citation">Derwyn Severy and Paul Barbour; <cite>Acceleration Accuracy: Analyses of High-Speed Camera Film</cite>, Journal of the SMPTE ( Volume: 65, Issue: 2, February 1956); SMPTE, 1956. Available at <a href="https://doi.org/10.5594/J14509" target="_blank" rel="noopener">https://doi.org/10.5594/J14509</a></span>
SMPTE's HTML Pub
Preview:
Derwyn Severy and Paul Barbour; Acceleration Accuracy: Analyses of High-Speed Camera Film, Journal of the SMPTE ( Volume: 65, Issue: 2, February 1956); SMPTE, 1956
doi: 10.5594/J14509
url: https://doi.org/10.5594/J14509
doi: 10.5594/J14509
url: https://doi.org/10.5594/J14509
Snippet:
<li> Derwyn Severy and Paul Barbour; <cite id="bib-10-5594-j14509">Acceleration Accuracy: Analyses of High-Speed Camera Film</cite>, Journal of the SMPTE ( Volume: 65, Issue: 2, February 1956); SMPTE, 1956 <span class="doi">10.5594/J14509</span> </li>