Cinematographic Instrumentation in Cineradiology
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Abbreviated Title
- J SMPTE
- Volume
- 76, No. 11, pp. 1090–1094
- Abstract
- A special 35mm motion-picture camera now being used routinely for cardiac angiography has a nonstandard format permitting the phosphor image of the intensifier to be recorded as a 25-mm circle. The increase in picture size has improved definition, particularly with high-speed films (Cineflure) with which coarse grain structure has detracted from quality. The shutter has a 180° open phase when used with triggered x-ray emission, a design which better records movement because the x-ray exposure may now be twice as long as previously. No increase in movement blur has been detected in individual frames by increasing pulse widths to 10 ms at a rate of 50 frames (56. 25 in.)/s. The film is advanced six sprocket holes at a time instead of the standard four; therefore it was necessary to design and build a prism-type editor for diagnosis. This apparatus projects a 9-in. picture onto the screen. An optical step-printer head has been designed for the reduction of the nonstandard 35mm pictures onto standard 16mm film. Some detail is necessarily lost in this reduction process, but since the 16mm printing stock has a very high resolving power, this detail loss is difficult to detect. Reduction printing onto 16mm film has also meant that the gradation of the original negative can be controlled and if necessary varied to suit the particular subject being reproduced.
- Publication Date
- 1967-11-01
- DOI
10.5594/J13665- ISSN
- Print:
0361-4573 - Link
- https://doi.org/10.5594/J13665
- Author(s)
- J. H. HoodDept. of Surgery, University of Queensland, Royal Brisbane Hospital, Herston, Brisbane, Queensland, Australia; and P. R. W. Jones, South East Engineering Co., Herston, Qld., AustraliaP. R. W. JonesDept. of Surgery, University of Queensland, Royal Brisbane Hospital, Herston, Brisbane, Queensland, Australia; and P. R. W. Jones, South East Engineering Co., Herston, Qld., Australia
- Copyright
- © 1967 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- 1. Lusted L. B. , “Current technical problems in cinefluorography,” Radiology , 73 : 527 – 530 , Oct. 1959 . EXTERNAL
- 10. Hood J. H. , “Cineradiology with image intensification,” Brit. J. Radiol. , 39 : 590 – 596 , Aug. 1966 . EXTERNAL
- 11. Wheeler L. J. , Principles of Cinematography , Fountain Press , London , 1963 . EXTERNAL
- 12. Hood J. H. , “An optical step printer for cineradiographs,” J. Coll. Radiol. Aust. , 8 : 292 – 294 , Oct. 1964 . EXTERNAL
- 2. Klatte E. C. Campbell J. A. Lurie P. R. , “Technical factors in selective cinecardioangiography,” Radiology , 73 : 539 – 547 , Oct. 1959 . EXTERNAL
- 3. Campbell J. A. Klatte E. C. Shalkovski R. A. , “Factors influencing image and quality in cineroentgenography,” Amer. J. Roentgenol. , 83 : 345 – 353 , Feb. 1960 . EXTERNAL
- 4. Morgan R. H. , “The performance of screen intensification and cinefluorographic systems,” Amer. J. Roentgenol. , 86 : 1027 – 1039 , Dec. 1961 . EXTERNAL
- 5. Sewell W. H. Takaro T. Rayl J. E. Quinn R. P. , “A technique using coronary cinearteriography for surgical and physiologic studies in dogs,” Amer. J. Roentgenol. , 88 : 49 – 55 , July 1962 . EXTERNAL
- 6. Sones F. M. — Personal communication. EXTERNAL
- 7. Klopping J. C. Abrams H. L. , “Optical reduction printing in a radiology department,” Radiology , 80 : 994 – 999 , June 1963 . EXTERNAL
- 8. Samuel E. Sumerling M. D. , “An assessment of the use of the 70mm camera in radiological practice,” Brit. J. Radiol. , 37 : 620 – 624 , Aug. 1964 . EXTERNAL
- 9. Campbell J. A. Tampas J. P. Gray D. D. , “Square frame 16mm cineradiography,” Radiology , 82 : 520 – 524 , Mar. 1964 . EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J13665.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
J. H. Hood and P. R. W. Jones; Cinematographic Instrumentation in Cineradiology, Journal of the SMPTE ( Volume: 76, Issue: 11, November 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J13665
Snippet:
J. H. Hood and P. R. W. Jones; Cinematographic Instrumentation in Cineradiology, Journal of the SMPTE ( Volume: 76, Issue: 11, November 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J13665
HTML (ISO 690 compliant)
Preview:
J. H. Hood and P. R. W. Jones; Cinematographic Instrumentation in Cineradiology, Journal of the SMPTE ( Volume: 76, Issue: 11, November 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J13665
Snippet:
<span class="citation">J. H. Hood and P. R. W. Jones; <cite>Cinematographic Instrumentation in Cineradiology</cite>, Journal of the SMPTE ( Volume: 76, Issue: 11, November 1967); SMPTE, 1967. Available at <a href="https://doi.org/10.5594/J13665" target="_blank" rel="noopener">https://doi.org/10.5594/J13665</a></span>
SMPTE's HTML Pub
Preview:
J. H. Hood and P. R. W. Jones; Cinematographic Instrumentation in Cineradiology, Journal of the SMPTE ( Volume: 76, Issue: 11, November 1967); SMPTE, 1967
doi: 10.5594/J13665
url: https://doi.org/10.5594/J13665
doi: 10.5594/J13665
url: https://doi.org/10.5594/J13665
Snippet:
<li> J. H. Hood and P. R. W. Jones; <cite id="bib-10-5594-j13665">Cinematographic Instrumentation in Cineradiology</cite>, Journal of the SMPTE ( Volume: 76, Issue: 11, November 1967); SMPTE, 1967 <span class="doi">10.5594/J13665</span> </li>