API Build-data JSON Resources
Theme

Choose how MSRBot.io looks on this device.

Preference is stored in this browser only.

Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962)
[ACTIVE]

Closed-Circuit Television System for X-Ray Inspection

Metadata

Publisher
SMPTE — White Plains, NY, USA
Doc Type
Journal Article
Content Type
Original Research
Abbreviated Title
J SMPTE
Volume
71, No. 6, pp. 444–447
Abstract
Use of a closed-circuit television system as the direct-imaging device in conjunction with x-ray as a radiation source has made possible an instantaneous, in motion, inspection system for studying materials and structures. The TV camera uses a small-area x-ray sensitive pickup tube as the sensing device. The x-ray image displayed on the monitor picture tube is enlarged approximately 30×. The system performance is equivalent to results obtained from conventional x-ray imaging techniques for material thicknesses up to ¼ in. of steel.
Publication Date
1962-06-01
DOI
10.5594/J12123
ISSN
Print: 0361-4573
Link
https://doi.org/10.5594/J12123
Author(s)
Jay P. MitchellEngineering Experiment Station, Ohio State University, Columbus, Ohio
Merle L. RhotenEngineering Experiment Station, Ohio State University, Columbus, Ohio
Copyright
© 1962 Society of Motion Picture and Television Engineers, Inc.

Bibliographic Reference(s)

  • 1. O'Connor Donald T. , “Fluoroscopy and x-ray image devices,” Sec. 19, Nondestructive Testing Handbook , edited by Robert C. McMaster for Society for Nondestructive Testing Inc., Ronald Press Go. , 15 East 26 St., New York 10 , 1959 . EXTERNAL
  • 10. Allen J. W. McClung R. W. , “An electronic, high-resolution x-ray imaging system,” Oak Ridge National Laboratory Report , No. ORNL-2671, Aug. 11, 1959 , 19 pp. EXTERNAL
  • 11. Rose A. Lampert M. A. , “Gain-bandwidth product for photoconductors, ” RCA Review , 20 : 57 – 68 , 1959 . EXTERNAL
  • 12. McMaster R. C. , “New developments in xeroradiography,” Nondestructive Testing , 13 : No. 6 , 8 et seq., 1951 . EXTERNAL
  • 2. Allen B. DuMont Laboratories, Inc. , “Development of a remote electronic x-ray image pick-up system,” Final Report, Department of Defense, New York Ordnance District , Contract No. DA-30–069-ORD-1327, June 30, 1956; also Contract No. DA-30–069-505-ORD-2188, June 15, 1959 . EXTERNAL
  • 3. Weimar P. K. Forgue S. V. Goodrich R. R. , “The vidicon photocoaductlve camera tube, ” RCA Review , 12 : 306 – 313 , 1951 . EXTERNAL
  • 4. Vine B. H. Janes R. B. Veith F. S. , “Performance of the vidicon, a small developmental television camera tube, ” RCA Review , 13 : 3 – 10 , 1952 . EXTERNAL
  • 5. Heijne L. Schagen P. Bruining H. , “An experimental photoconductive camera tube for television , “Philips Tech. Rev. , 16 : No. 1 , 23 – 25 , 1954 . EXTERNAL
  • 6. Cope A. D. Rose A. , “X-ray noise observation using a photoconductive pickup tube, ” Jour. Appl. Phys. , 25 : No. 2 , 240 – 242 , 1954 . EXTERNAL
  • 7. Jacobs J. E. Berger H. , “Performance of a large area photoconductive x-ray pickup tube, ” Elec. Bug. , 72 : 158 – 161 , 1956 . EXTERNAL
  • 8. Cope A. D. , “A miniature vidicon of high sensitivity, ” RCA Review , 17 : 460 – 468 , 1956 . EXTERNAL
  • 9. Ochs S. A. Weimer P. K. , “Some new structure-type targets for the vidicon — an analysis of their operation, ” RCA Review , 19 : 49 – 61 , 1958 . EXTERNAL
Source Data (JSON)

Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J12123.json

Reference Tree

Explore all references and references to this document, as a navigable tree.

Open Reference Tree
Reference this Doc

Plain text (ISO 690 compliant)

Preview:
Jay P. Mitchell and Merle L. Rhoten; Closed-Circuit Television System for X-Ray Inspection, Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962); SMPTE, 1962. Available at https://doi.org/10.5594/J12123
Snippet:
Jay P. Mitchell and Merle L. Rhoten; Closed-Circuit Television System for X-Ray Inspection, Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962); SMPTE, 1962. Available at https://doi.org/10.5594/J12123

HTML (ISO 690 compliant)

Preview:
Jay P. Mitchell and Merle L. Rhoten; Closed-Circuit Television System for X-Ray Inspection, Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962); SMPTE, 1962. Available at https://doi.org/10.5594/J12123
Snippet:
<span class="citation">Jay P. Mitchell and Merle L. Rhoten; <cite>Closed-Circuit Television System for X-Ray Inspection</cite>, Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962); SMPTE, 1962. Available at <a href="https://doi.org/10.5594/J12123" target="_blank" rel="noopener">https://doi.org/10.5594/J12123</a></span>

SMPTE Icon SMPTE's HTML Pub

Preview:
Jay P. Mitchell and Merle L. Rhoten; Closed-Circuit Television System for X-Ray Inspection, Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962); SMPTE, 1962
doi: 10.5594/J12123
url: https://doi.org/10.5594/J12123
Snippet:
<li>
Jay P. Mitchell and Merle L. Rhoten; <cite id="bib-10-5594-j12123">Closed-Circuit Television System for X-Ray Inspection</cite>, Journal of the SMPTE ( Volume: 71, Issue: 6, June 1962); SMPTE, 1962
<span class="doi">10.5594/J12123</span>
</li>