Effective Spot Size in Beam Scanning Tubes
Metadata
- Publisher
- SMPTE
- Doc Type
- Journal Article
- Article Type
- research-article
- Abstract
- The Gaussian current distribution does not hold in practical electron beams because of aberrations, space-charge and masking conditions. Only an overall effect of the total current is useful for defining spot size; and thus, the observation of the visible spot boundaries on phosphor screens is adopted (telescope). Because of the prevailing bell-shaped current density distributions, this definition comes closest to a practical measure of spot size based on center peak brightness. Experimental evidence is given for the formation of vertically reduced spot sizes during beam scanning in form of ellipses, manifesting itself in a significant improvement on vertical picture resolution.
- Publication Date
- 1960-10-01
- DOI
10.5594/J09404- Link
- https://doi.org/10.5594/J09404
- Author(s)
- Aurelius Sandor
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J09404.json
Reference this Doc
Plain text (ISO 690 compliant)
Preview:
Aurelius Sandor; Effective Spot Size in Beam Scanning Tubes, Journal of the SMPTE ( Volume: 69, Issue: 10, October 1960); SMPTE, 1960. Available at https://doi.org/10.5594/J09404
Snippet:
Aurelius Sandor; Effective Spot Size in Beam Scanning Tubes, Journal of the SMPTE ( Volume: 69, Issue: 10, October 1960); SMPTE, 1960. Available at https://doi.org/10.5594/J09404
HTML (ISO 690 compliant)
Preview:
Aurelius Sandor; Effective Spot Size in Beam Scanning Tubes, Journal of the SMPTE ( Volume: 69, Issue: 10, October 1960); SMPTE, 1960. Available at https://doi.org/10.5594/J09404
Snippet:
<span class="citation">Aurelius Sandor; <cite>Effective Spot Size in Beam Scanning Tubes</cite>, Journal of the SMPTE ( Volume: 69, Issue: 10, October 1960); SMPTE, 1960. Available at <a href="https://doi.org/10.5594/J09404" target="_blank" rel="noopener">https://doi.org/10.5594/J09404</a></span>
SMPTE's HTML Pub
Preview:
Aurelius Sandor; Effective Spot Size in Beam Scanning Tubes, Journal of the SMPTE ( Volume: 69, Issue: 10, October 1960); SMPTE, 1960
doi: 10.5594/J09404
url: https://doi.org/10.5594/J09404
doi: 10.5594/J09404
url: https://doi.org/10.5594/J09404
Snippet:
<li> Aurelius Sandor; <cite id="bib-10-5594-j09404">Effective Spot Size in Beam Scanning Tubes</cite>, Journal of the SMPTE ( Volume: 69, Issue: 10, October 1960); SMPTE, 1960 <span class="doi">10.5594/J09404</span> </li>