Transient-Test Methods of Checking Television Transmitter Performance
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Volume
- 74, No. 2, pp. 114–117
- Abstract
- Transient testing methods have advantages over conventional steady-state testing methods for transmitter as well as studio applications. A sine-squared transition signal not only more directly indicates the performance of the transmitter, but enables a known phase response to be maintained, with consequent picture-quality improvement. There are practical difficulties in obtaining absolute measurements, so Go-No-Go oscilloscope graticules are suggested for routine testing.
- Publication Date
- 1965-02-01
- DOI
10.5594/J09270- ISSN
- Print:
0361-4573 - Link
- https://doi.org/10.5594/J09270
- Author(s)
- M. W. S. BarlowCanadian Broadcasting Corp., 7925 Cote St. Luc Rd., Montreal 29, Que.
- Copyright
- © 1965 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- A New Graticule for Measuring Television Transmitter Frequency Response [Active]
- 2. Kennedy Ralph C. , “Sine squared pulses in TV system analysis,” Broadcast Engineering , Sept. 1960 ( Introductory treatment ). EXTERNAL
- 3. Potts K. H. , “The performance evaluation of television line and microwave links using sine squared test techniques,” Jour. Brit. IRE , Apr. 1963 (14 references). EXTERNAL
- 4. Osborne Peverett Wallace , “The K rating of television equipment and networks,” Jour. TV Soc. , 10 : no. 10 , June 1964 (19 references). EXTERNAL
- 5. Siocos C. A. , “Sine squared signal testing techniques for routine measurements,” CBC Plant Report 6:08:280, Oct. 1960 . EXTERNAL
- 6. “Combined sine squared and IRE scale graticule for Tektronix waveform monitors,” CBC Engineering Div. , Montreal , Report 7:22:6, Oct. 1962 . EXTERNAL
- 7. Television Transmitter Specification No. 871C , Australian Post Office Dept. EXTERNAL
- 8. Brownless S. F. , “Delay and transient problems in television broadcasting,” Australian Broadcasting Control Board , 497 Collins St., Melbourne Cl, Australia , Technical Services Report No. 18 (55 references). EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J09270.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
M. W. S. Barlow; Transient-Test Methods of Checking Television Transmitter Performance, Journal of the SMPTE ( Volume: 74, Issue: 2, February 1965); SMPTE, 1965. Available at https://doi.org/10.5594/J09270
Snippet:
M. W. S. Barlow; Transient-Test Methods of Checking Television Transmitter Performance, Journal of the SMPTE ( Volume: 74, Issue: 2, February 1965); SMPTE, 1965. Available at https://doi.org/10.5594/J09270
HTML (ISO 690 compliant)
Preview:
M. W. S. Barlow; Transient-Test Methods of Checking Television Transmitter Performance, Journal of the SMPTE ( Volume: 74, Issue: 2, February 1965); SMPTE, 1965. Available at https://doi.org/10.5594/J09270
Snippet:
<span class="citation">M. W. S. Barlow; <cite>Transient-Test Methods of Checking Television Transmitter Performance</cite>, Journal of the SMPTE ( Volume: 74, Issue: 2, February 1965); SMPTE, 1965. Available at <a href="https://doi.org/10.5594/J09270" target="_blank" rel="noopener">https://doi.org/10.5594/J09270</a></span>
SMPTE's HTML Pub
Preview:
M. W. S. Barlow; Transient-Test Methods of Checking Television Transmitter Performance, Journal of the SMPTE ( Volume: 74, Issue: 2, February 1965); SMPTE, 1965
doi: 10.5594/J09270
url: https://doi.org/10.5594/J09270
doi: 10.5594/J09270
url: https://doi.org/10.5594/J09270
Snippet:
<li> M. W. S. Barlow; <cite id="bib-10-5594-j09270">Transient-Test Methods of Checking Television Transmitter Performance</cite>, Journal of the SMPTE ( Volume: 74, Issue: 2, February 1965); SMPTE, 1965 <span class="doi">10.5594/J09270</span> </li>