A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Volume
- 76, No. 8, pp. 800–801
- Abstract
- An animal table actuated by a high precision multiple hydraulic servo mechanism, which eliminates all rack-and-pinion movements, was built for field searching and focusing under the microscope. Thus, the specimen carrier serves as its own mechanical stage with the laboratory animal, accessory supports and optional remote control micromanipulators. The machine can move in 0.3-μm increments or by continuous feed. Vibration damping elements isolate the specimen and microscope from the camera and environment.
- Publication Date
- 1967-08-01
- DOI
10.5594/J09125- ISSN
- Print:
0361-4573 - Link
- https://doi.org/10.5594/J09125
- Author(s)
- Nydia L. MeyersDept. of Obstetrics and Gynecology, University of Michigan, Wayne County General Hospital, Eloise, Mich. 48132.Charles L. SchneiderDept. of Obstetrics and Gynecology, University of Michigan, Wayne County General Hospital, Eloise, Mich. 48132.
- Copyright
- © 1967 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- Intravital Cinemicrostrob: A Vertical Optical Bench for Epicondenser Reflected Dark Field Illumination [Active]
- 1. Microscopy, Micro and Macro Photography , (Special Issue), Laboratory Management , 5 , No. 1, 1967 , United Business Publications, Industrial & Scientific Div. , 200 Madison Ave., New York, N.Y. 10016 . EXTERNAL
- 2. Schneider Charles L. Meyers Nydia L. , “Point source stroboscopic color cinemicrography of the rabbit pulmonary arteriolar circulation,” The Microscope and Crystal Front , Microscope Publications Ltd. , London , 1967 (in press). EXTERNAL
- 3. Schneider C. L. Meyers N. L. Chaplick M. J. Schneider D. N. , “Dark-field pulmonary cinemicrography: Fibrination (as in material abruptio placentae) versus meconium embolism (as in amniotic embolism),” Bibl. Anal. 9 : 541 , 1967 . EXTERNAL
- 4. Schneider C. L. Schneider D. N. , “Intravital cinemicrostrob for pulmonary arteriolar blood flow. Point source stroboscopy up to 400 frames/s: synchronization, flicker fusion, modeling and collimation for three dimensional differentiation.” Proc. Fifth National Biomedical Instrumentation Symposium, Instrument Society of America , 1967 , Pittsburgh. EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J09125.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
Nydia L. Meyers and Charles L. Schneider; A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues, Journal of the SMPTE ( Volume: 76, Issue: 8, August 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J09125
Snippet:
Nydia L. Meyers and Charles L. Schneider; A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues, Journal of the SMPTE ( Volume: 76, Issue: 8, August 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J09125
HTML (ISO 690 compliant)
Preview:
Nydia L. Meyers and Charles L. Schneider; A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues, Journal of the SMPTE ( Volume: 76, Issue: 8, August 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J09125
Snippet:
<span class="citation">Nydia L. Meyers and Charles L. Schneider; <cite>A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues</cite>, Journal of the SMPTE ( Volume: 76, Issue: 8, August 1967); SMPTE, 1967. Available at <a href="https://doi.org/10.5594/J09125" target="_blank" rel="noopener">https://doi.org/10.5594/J09125</a></span>
SMPTE's HTML Pub
Preview:
Nydia L. Meyers and Charles L. Schneider; A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues, Journal of the SMPTE ( Volume: 76, Issue: 8, August 1967); SMPTE, 1967
doi: 10.5594/J09125
url: https://doi.org/10.5594/J09125
doi: 10.5594/J09125
url: https://doi.org/10.5594/J09125
Snippet:
<li> Nydia L. Meyers and Charles L. Schneider; <cite id="bib-10-5594-j09125">A Three-Axis Micro-Positioning Machine for Cinemicrography of Living Tissues</cite>, Journal of the SMPTE ( Volume: 76, Issue: 8, August 1967); SMPTE, 1967 <span class="doi">10.5594/J09125</span> </li>