Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Abbreviated Title
- J SMPTE
- Volume
- 76, No. 3, pp. 216–224
- Abstract
- The problems of time-lapse cinemicrography of cell cultures differ greatly from those of still photomicrography of fixed preparations. The cost of commercial equipment for a complete setup is too high for the small laboratory. Utilizing existing equipment, some purchased components and some equipment constructed by the engineering department of the Isaac Albert Research Institute, a time-lapse unit was assembled. Available components and the specially designed repetitive electronic flash unit, incubator and pump are discussed.
- Publication Date
- 1967-03-01
- DOI
10.5594/J07057- ISSN
- Print:
0361-4573 - Link
- https://doi.org/10.5594/J07057
- Author(s)
- Herbert A. FischlerIsaac Albert Research Institute, Jewish Chronic Disease Hospital, 86 E. 49 St., Brooklyn, N.Y. 11203
- Copyright
- © 1967 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- 1. Ambrose E. J. , “The use of the interference microscope for the study of cell movements and quantitative analysis of changes in growing cells,” in Cinemicrography in Cell Biology by Rose George C. , Academic Press , 111 Fifth Ave., N.Y. , 1963 . EXTERNAL
- 2. Fischler H. A. , “Design of a phase contrast time-lapse cinemicrographic unit,” J. Biol. Phot. Assn. , 34 : 53 – 82 , No. 2 , May 1966 . EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J07057.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
Herbert A. Fischler; Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations, Journal of the SMPTE ( Volume: 76, Issue: 3, March 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J07057
Snippet:
Herbert A. Fischler; Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations, Journal of the SMPTE ( Volume: 76, Issue: 3, March 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J07057
HTML (ISO 690 compliant)
Preview:
Herbert A. Fischler; Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations, Journal of the SMPTE ( Volume: 76, Issue: 3, March 1967); SMPTE, 1967. Available at https://doi.org/10.5594/J07057
Snippet:
<span class="citation">Herbert A. Fischler; <cite>Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations</cite>, Journal of the SMPTE ( Volume: 76, Issue: 3, March 1967); SMPTE, 1967. Available at <a href="https://doi.org/10.5594/J07057" target="_blank" rel="noopener">https://doi.org/10.5594/J07057</a></span>
SMPTE's HTML Pub
Preview:
Herbert A. Fischler; Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations, Journal of the SMPTE ( Volume: 76, Issue: 3, March 1967); SMPTE, 1967
doi: 10.5594/J07057
url: https://doi.org/10.5594/J07057
doi: 10.5594/J07057
url: https://doi.org/10.5594/J07057
Snippet:
<li> Herbert A. Fischler; <cite id="bib-10-5594-j07057">Time-Lapse Cinemicrography of Tissue Cultures Utilizing Phase-Contrast Optics: Design and Construction Considerations</cite>, Journal of the SMPTE ( Volume: 76, Issue: 3, March 1967); SMPTE, 1967 <span class="doi">10.5594/J07057</span> </li>