- Abstract
- In a discussion of the preservation of prime film and magnetic elements, the issue of fire suppression and how it impacts safety and the environment must be addressed. Water, common to all mandated sprinkler systems, can damage more material than it protects, causing substantial and unnecessary financial loss due to business interruption and downtime. Halon, a superior fire suppressant used to protect motion-picture and television elements as well as electronic equipment, has been phased out, along with other ozone-depleting chlorofluorocarbons (CFCs), as part of the Montreal Protocol. As new fire suppressing agents are introduced, complex choices must be made regarding new construction; especially important to consider is the upgrading of systems from water sprinklers to gaseous agents or retrofitting Halon 1301 systems.
- Publication Date
- 1994-08-01
- DOI
10.5594/J06462- ISSN
- Print:
0036-1682 - Link
- https://doi.org/10.5594/J06462
- Author(s)
- Chris R. ReimerFacilities Protection Systems, Inc., Anaheim, CA 92806.Milton R. ShefterMiljoy Enterprises, Inc., Beverly Hills, CA 90210.
- Copyright
- © 1994 Society of Motion Picture and Television Engineers, Inc.
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J06462.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
Chris R. Reimer and Milton R. Shefter; Clean-Agent Fire Suppression Alternatives, SMPTE Journal ( Volume: 103, Issue: 8, August 1994); SMPTE, 1994. Available at https://doi.org/10.5594/J06462
Snippet:
Chris R. Reimer and Milton R. Shefter; Clean-Agent Fire Suppression Alternatives, SMPTE Journal ( Volume: 103, Issue: 8, August 1994); SMPTE, 1994. Available at https://doi.org/10.5594/J06462
HTML (ISO 690 compliant)
Preview:
Chris R. Reimer and Milton R. Shefter; Clean-Agent Fire Suppression Alternatives, SMPTE Journal ( Volume: 103, Issue: 8, August 1994); SMPTE, 1994. Available at https://doi.org/10.5594/J06462
Snippet:
<span class="citation">Chris R. Reimer and Milton R. Shefter; <cite>Clean-Agent Fire Suppression Alternatives</cite>, SMPTE Journal ( Volume: 103, Issue: 8, August 1994); SMPTE, 1994. Available at <a href="https://doi.org/10.5594/J06462" target="_blank" rel="noopener">https://doi.org/10.5594/J06462</a></span>
SMPTE's HTML Pub
Preview:
Chris R. Reimer and Milton R. Shefter; Clean-Agent Fire Suppression Alternatives, SMPTE Journal ( Volume: 103, Issue: 8, August 1994); SMPTE, 1994
doi: 10.5594/J06462
url: https://doi.org/10.5594/J06462
doi: 10.5594/J06462
url: https://doi.org/10.5594/J06462
Snippet:
<li> Chris R. Reimer and Milton R. Shefter; <cite id="bib-10-5594-j06462">Clean-Agent Fire Suppression Alternatives</cite>, SMPTE Journal ( Volume: 103, Issue: 8, August 1994); SMPTE, 1994 <span class="doi">10.5594/J06462</span> </li>
Referenced By
- PBS: Through the A-to-D Converter [Active]