A Motion Picture Laboratory Sensitometer
Metadata
- Publisher
- SMPTE — White Plains, NY, USA
- Doc Type
- Journal Article
- Content Type
- Original Research
- Abbreviated Title
- J SMPE
- Volume
- 17, No. 4, pp. 536–559
- Abstract
- This instrument is one giving a time scale of exposure. The exposure scale consists of 21 steps in which the exposure increases by consecutive powers of √2. The modulation of exposure time is accomplished by means of a sectored drum driven by a synchronous motor. Two standardized electric incandescent lamps are provided, one for use in exposing negative materials and one for positive materials. These are mounted in pre-positioned bases, the lamp itself being permanently set in position at the factory so that when the base is placed on its support by means of two dowel pins the filament of the lamp must lie upon the optical axis of the instrument and in register with the distance indicating scale. Standardized dyed gelatin filters are provided so that for positive materials the exposure illumination has a color temperature of approximately 3000°K., while for negative materials the color temperature is approximately 5400°K., approximately matching mean noon sunlight in quality. Electrical measuring instruments for controlling the standard lamps are an integral part of the sensitometer. Convenient guides for positioning the film to be exposed are provided as well as a roll holder for carrying a supply of raw stock. It is estimated that the probable error in exposure does not exceed ± 2.5 per cent.
- Publication Date
- 1931-10-01
- DOI
10.5594/J05570- ISSN
- Print:
0097-5834 - Link
- https://doi.org/10.5594/J05570
- Author(s)
- Loyd A. JonesEastman Kodak Co., Rochester, N. Y.
- Copyright
- © 1931 Society of Motion Picture and Television Engineers, Inc.
Bibliographic Reference(s)
- 1 Mees C. E. K. Sheppard S. E. : “On Instruments for Sensitometric Investigation, with an Historical Résumé,” Phot. J. , 44 ( n. s. 28 ) ( 1904 ), p. 200 . EXTERNAL
- 2 Nietz A. H. : “Theory of Development, Monograph No. 2 from the Kodak Research Laboratories” Eastman Kodak Company ( 1922 ). EXTERNAL
- 3 Jones L. A. : “Photographic Sensitometry,” J. Soc. Mot. Pict. Eng. , XVII ( 1931 ), p. 491 . EXTERNAL
- 4 Davis R. Gibson K. S. : “Artificial Sunlight for Photographic Sensitometry,” Trans. Soc. Mot. Pict. Eng. , XII ( 1928 ), p. 225 . “Filters for the Reproduction of Sunlight and Daylight and the Determination of Color Temperature,” Misc. Publ., Bur. of Standards (1931), No. 114. EXTERNAL
Source Data (JSON)
Full registry record with provenance metadata. Open directly: /api/doc/10.5594-J05570.json
Reference Tree
Explore all references and references to this document, as a navigable tree.
Open Reference TreeReference this Doc
Plain text (ISO 690 compliant)
Preview:
Loyd A. Jones; A Motion Picture Laboratory Sensitometer, Journal of the Society of Motion Picture Engineers ( Volume: 17, Issue: 4, October 1931); SMPTE, 1931. Available at https://doi.org/10.5594/J05570
Snippet:
Loyd A. Jones; A Motion Picture Laboratory Sensitometer, Journal of the Society of Motion Picture Engineers ( Volume: 17, Issue: 4, October 1931); SMPTE, 1931. Available at https://doi.org/10.5594/J05570
HTML (ISO 690 compliant)
Preview:
Loyd A. Jones; A Motion Picture Laboratory Sensitometer, Journal of the Society of Motion Picture Engineers ( Volume: 17, Issue: 4, October 1931); SMPTE, 1931. Available at https://doi.org/10.5594/J05570
Snippet:
<span class="citation">Loyd A. Jones; <cite>A Motion Picture Laboratory Sensitometer</cite>, Journal of the Society of Motion Picture Engineers ( Volume: 17, Issue: 4, October 1931); SMPTE, 1931. Available at <a href="https://doi.org/10.5594/J05570" target="_blank" rel="noopener">https://doi.org/10.5594/J05570</a></span>
SMPTE's HTML Pub
Preview:
Loyd A. Jones; A Motion Picture Laboratory Sensitometer, Journal of the Society of Motion Picture Engineers ( Volume: 17, Issue: 4, October 1931); SMPTE, 1931
doi: 10.5594/J05570
url: https://doi.org/10.5594/J05570
doi: 10.5594/J05570
url: https://doi.org/10.5594/J05570
Snippet:
<li> Loyd A. Jones; <cite id="bib-10-5594-j05570">A Motion Picture Laboratory Sensitometer</cite>, Journal of the Society of Motion Picture Engineers ( Volume: 17, Issue: 4, October 1931); SMPTE, 1931 <span class="doi">10.5594/J05570</span> </li>
Referenced By
- Progress in the Motion Picture Industry [Active]
- A Processing Control Sensitometer [Active]