    "abstract": "The human visual system has better acuity for vertical and horizontal detail than it does for diago nal detail. Scenes statistically have less detail on the diagonal. For these reasons diagonal sampling produces a sharper perceived image than a cardinally sampled image for the same number of pixels. If the sampling pattern of a 720 line 60P image is rotated 45 degrees with the same number of pixels it will look sharper then either the 720 line 60P image or a 1080 line 30I image. This rotated pattern produces a diagonally sampled 1810×1018 60P image. A slight increase in the number of pixels and lines produces a diagonally sampled 1920×1080 60P image. A diagonally sampled 1920×1080 60P image has the same bit rate as 1920×1080 30I image with higher perceived sharpness. This pattern has 960 pixels per line. Two lines can be transmitted dot sequentially (One line on the odd pixels and the other on the even pixels) to give 1920 samples per line. A transmission in this format is compatible with 1920×1080 30I displays. However, progressive display must be used to avoid interlace artifacts. By using synchronous spot wobble, an interlaced display can display a diagonally sampled image progressively without changing the horizontal scan rate.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "authors": [
      {
        "affiliation": "Florida Atlantic University Boca Raton, FL 33431",
        "name": "William E. Glenn"
      }
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Object form (schema 2.3.0) migrated from string form via migrateAuthorsToObjectForm.js; bio/affiliation backfilled from _source/SMPTE/HIGHWIRE/ NLM <contrib-group>+<aff>+<bio>",
      "source": "parsed",
      "updated": "2026-06-23T00:04:25.562Z",
      "version": "authors-migrate-object-form@v1"
    },
    "contentType": "orig-research",
    "contentType$meta": {
      "confidence": "high",
      "note": "Canonical-confirmed full paper (summary-abstract set is orig-research in the SMPTE canonical repos); HIGHWIRE-era abstract label was a delivery artifact",
      "originalValue": "summary-abstract",
      "source": "resolved",
      "updated": "2026-07-09T19:12:47.628Z",
      "version": "contenttype-fixes@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      },
      "year": "2002",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docId": "10.5594-M00219",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/M00219",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docLabel": "SMPTE Meetings and Conferences ( February 2002)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docTitle": "A 1920×1080 60P System that is Compatible with a 1920×1080 30I Format",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docType": "Conference Paper",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE conference paper",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "doi": "10.5594/M00219",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "href": "https://doi.org/10.5594/M00219",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/M00219",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "number": "5",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "pages": "1–7",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "publicationDate": "2002-02-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "references": {
      "bibliographic": [
        "10.5594-J04128",
        "orphan/10.5594-M00219/bibr2-10.5594_M00219",
        "orphan/10.5594-M00219/bibr3-10.5594_M00219",
        "orphan/10.5594-M00219/bibr4-10.5594_M00219",
        "orphan/10.5594-M00219/bibr5-10.5594_M00219",
        "orphan/10.5594-M00219/bibr6-10.5594_M00219"
      ],
      "bibliographic$meta": {
        "confidence": "medium",
        "note": "Extracted from NLM <ref-list> via extractSmpteConferenceRefs.js (precheck-reuse)",
        "source": "parsed",
        "updated": "2026-07-06T20:02:43.384Z"
      }
    },
    "resolvedHref": "https://journal.smpte.org/conferences/36th%20SMPTE%20Annual%20Advanced%20Motion%20Imaging%20Conference/1/",
    "resolvedHref$meta": {
      "confidence": "high",
      "note": "Backfilled from url.validate report #resolvedHref",
      "originalValue": null,
      "source": "resolved",
      "updated": "2026-06-19T20:59:07.438Z"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — conference papers default active",
        "source": "inferred",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      }
    },
    "volume": "2002",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2002_5/10.5594_M00219.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    }
  }
}