    "abstract": "With the emergence of lasers as a replacement for xenon arc lamps in ultra-high brightness digital projection applications, it is desirable to preserve the best possible image. Speckle is one aspect of image quality that has been fundamentally difficult to measure, due the unique physical characteristics of coherent light and the absence of a single focal plane for the speckle image. In this paper, the success criteria for a speckle measurement method are identified, and industry work to date is surveyed. The challenges of measuring low values of speckle are identified as: a large number of variables; system interaction among variables; and noise. The concept of Uniform Field Contrast Ratio (UFCR) is introduced to distinguish between Speckle Contrast Ratio (SCR) and contrast due to non-speckle noise sources that can affect SCR measurement. We expect that ultimately two different measurement methods will be needed: one optimized for low noise, and one optimized for commercial cinema installations.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "authors": [
      {
        "affiliation": "CR Media Technologies, Westford, MA, USA rickposch@comcast.net",
        "name": "Rick Posch"
      },
      {
        "affiliation": "ReaID, Inc. Beverly Hills, CA, USA plude@reald.com",
        "name": "Pete Ludé"
      }
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Object form (schema 2.3.0) migrated from string form via migrateAuthorsToObjectForm.js; bio/affiliation backfilled from _source/SMPTE/HIGHWIRE/ NLM <contrib-group>+<aff>+<bio>",
      "source": "parsed",
      "updated": "2026-06-23T00:04:25.562Z",
      "version": "authors-migrate-object-form@v1"
    },
    "contentType": "orig-research",
    "contentType$meta": {
      "confidence": "high",
      "note": "Canonical-confirmed full paper (summary-abstract set is orig-research in the SMPTE canonical repos); HIGHWIRE-era abstract label was a delivery artifact",
      "originalValue": "summary-abstract",
      "source": "resolved",
      "updated": "2026-07-09T19:12:47.628Z",
      "version": "contenttype-fixes@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      },
      "year": "2014",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docId": "10.5594-M001585",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/M001585",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docLabel": "SMPTE Meetings and Conferences ( October 2014)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docTitle": "Development of an Accurate and Repeatable Measurement Method for Speckle in Laser Illuminated Projectors",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "docType": "Conference Paper",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE conference paper",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "doi": "10.5594/M001585",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "href": "https://doi.org/10.5594/M001585",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/M001585",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "keywords": [
      "Measurement",
      "Laser",
      "Projector",
      "Projection"
    ],
    "keywords$meta": {
      "confidence": "high",
      "note": "Backfilled from SMPTE canonical repository index_terms, mapped through controlledKeywords + curated synonym folds (keywordVocabDecisions.json) (smpte-canonical-audit/canonicalLibrary.*.json)",
      "originalValue": null,
      "source": "parsed",
      "updated": "2026-07-08T23:52:57.741Z",
      "version": "smpte-canonical-repo@v1"
    },
    "number": "10",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "pages": "1–12",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "publicationDate": "2014-10-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    },
    "references": {
      "bibliographic": [
        "orphan/10.5594-M001585/bibr1-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr2-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr3-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr4-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr5-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr6-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr7-J-SMSE0011-0001",
        "orphan/10.5594-M001585/bibr8-J-SMSE0011-0001"
      ],
      "bibliographic$meta": {
        "confidence": "medium",
        "note": "Extracted from NLM <ref-list> via extractSmpteConferenceRefs.js (precheck-reuse)",
        "source": "parsed",
        "updated": "2026-07-06T20:02:43.384Z"
      }
    },
    "resolvedHref": "https://journal.smpte.org/conferences/SMPTE%202014%20Annual%20Technical%20Conference%20&%20Exhibition/51/",
    "resolvedHref$meta": {
      "confidence": "high",
      "note": "Backfilled from url.validate report #resolvedHref",
      "originalValue": null,
      "source": "resolved",
      "updated": "2026-06-19T20:59:07.438Z"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — conference papers default active",
        "source": "inferred",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-conference-paper-nlm@v1"
      }
    },
    "volume": "2014",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/ORIGINAL SAMPLES/Conferences/smptem_2014_10/smptem_2014_10.xml/10.5594_M001585.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-conference-paper-nlm@v1"
    }
  }
}