{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-07-09T21:16:49.031Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J17298",
  "document": {
    "abbrevTitle": "SMPTE Mot. Imag. J",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "More than 20 years ago, tubes were replaced with charge-coupled device (CCD) imagers as the image capture element in a broadcast camera. After maturing for many years, present CCDs far exceed the performance of tubes. With the arrival of 1080p50/60, the transition from CCDs to complementary metal oxide semiconductor (CMOS) imagers is inevitable. Laws of physics dictate that each packet of photons has shot noise. This poses a physical limit to the performance of a camera, especially in the arena of interchanging frames per second, pixel dimensions, and lens f-number. This aspect raises some interesting challenges with regard to 1080p50 and beyond. Recently, a full high-definition television (HDTV) CMOS imager was developed for use in broadcast cameras that competes in performance with CCDs. This paper discusses underlying issues such as resolution, pixel size, noise, sensitivity, and frame rate in relation to CCDs and CMOS imagers for broadcast use.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      {
        "affiliation": "Grass Valley, the Netherlands.",
        "bio": "Peter G. M. Centen , Grass Valley, the Netherlands. Photograph and biography not available at time of publication.",
        "name": "Peter G. M. Centen"
      }
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Object form (schema 2.3.0) migrated from string form via migrateAuthorsToObjectForm.js; bio/affiliation backfilled from _source/SMPTE/HIGHWIRE/ NLM <contrib-group>+<aff>+<bio>",
      "source": "parsed",
      "updated": "2026-06-23T00:04:25.562Z",
      "version": "authors-migrate-object-form@v1"
    },
    "contentType": "orig-research",
    "contentType$meta": {
      "confidence": "high",
      "note": "Cross-filled from SMPTE canonical repository import (smpte-canonical-audit/canonicalLibrary.*.json); previous value was a placeholder",
      "originalValue": "other",
      "source": "parsed",
      "updated": "2026-07-07T23:39:31.295Z",
      "version": "smpte-canonical-repo@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "2010",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J17298",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J17298",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "SMPTE Motion Imaging Journal ( Volume: 119, Issue: 8, 2010)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Next-Generation CMOS Imager for Broadcast Cameras",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J17298",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J17298",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J17298",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "electronic": "2160-2492",
      "electronic$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "print": "1545-0279",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08202015 BACKFILE JOURNAL FRESH/smptej_119_8/MIJR15Vol119No8.xml)",
      "source": "parsed",
      "updated": "2026-06-17T00:17:09.425Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "journalTitle": "SMPTE Motion Imaging Journal",
    "journalTitle$meta": {
      "confidence": "high",
      "note": "Era-accurate journal title from SMPTE canonical repository (periodical parent at time of publication) (smpte-canonical-audit/canonicalLibrary.*.json)",
      "originalValue": null,
      "source": "parsed",
      "updated": "2026-07-08T00:35:38.133Z",
      "version": "smpte-canonical-repo@v1"
    },
    "number": "8",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "53–58",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "2010-11-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Month corrected from SMPTE canonical repository (registry had Jan-1 placeholder) (smpte-canonical-audit/canonicalLibrary.*.json)",
      "originalValue": "2010-01-01",
      "source": "parsed",
      "updated": "2026-07-08T00:35:38.133Z",
      "version": "smpte-canonical-repo@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08202015 BACKFILE JOURNAL FRESH/smptej_119_8/MIJR15Vol119No8.xml)",
        "source": "parsed",
        "updated": "2026-06-17T00:17:09.425Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "references": {
      "bibliographic": [
        "orphan/10.5594-J17298/bibr1-10.5594_J17298",
        "orphan/10.5594-J17298/bibr2-10.5594_J17298",
        "orphan/10.5594-J17298/bibr3-10.5594_J17298",
        "orphan/10.5594-J17298/bibr4-10.5594_J17298",
        "orphan/10.5594-J17298/bibr5-10.5594_J17298",
        "orphan/10.5594-J17298/bibr6-10.5594_J17298",
        "orphan/10.5594-J17298/bibr7-10.5594_J17298",
        "orphan/10.5594-J17298/bibr8-10.5594_J17298",
        "orphan/10.5594-J17298/bibr9-10.5594_J17298",
        "orphan/10.5594-J17298/bibr10-10.5594_J17298",
        "orphan/10.5594-J17298/bibr11-10.5594_J17298",
        "orphan/10.5594-J17298/bibr12-10.5594_J17298",
        "orphan/10.5594-J17298/bibr13-10.5594_J17298",
        "orphan/10.5594-J17298/bibr14-10.5594_J17298",
        "orphan/10.5594-J17298/bibr15-10.5594_J17298",
        "orphan/10.5594-J17298/bibr16-10.5594_J17298"
      ],
      "bibliographic$meta": {
        "confidence": "medium",
        "note": "Extracted from NLM <ref-list> via extractSmpteJournalRefs.js (orphan-slug-mint)",
        "source": "parsed",
        "updated": "2026-07-06T18:21:02.558Z"
      }
    },
    "resolvedHref": "https://journal.smpte.org/periodicals/SMPTE%20Motion%20Imaging%20Journal/119/8/18/",
    "resolvedHref$meta": {
      "confidence": "high",
      "note": "Backfilled from url.validate report #resolvedHref",
      "originalValue": null,
      "source": "resolved",
      "updated": "2026-06-19T20:59:07.436Z"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal papers default active",
        "source": "inferred",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "119",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J17298.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}