{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J16747",
  "document": {
    "abbrevTitle": "J SMPTE",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "The present state of film scanning in relation to the FCC standard is noted. The advantages of the coincidence of the film's movement with the vertical scanning blank are emphasized, especially with respect to the scanning of color films. A flying-spot color scanner for 16mm film without color registration errors has been designed with a pneumatic fast-action pulldown movement that advances the film within 1.14 ms. Image and sound are ready for transmission 0.2 s after the start. A take-up device with constant torque motors that provide a constant tension on the film, even during the acceleration and deceleration phases, is explained. The system permits film reversal for monitoring. The particular advantages and properties are summarized.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "Heinrich Zahn",
      "Emil Sennhenn"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1967",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J16747",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J16747",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "Journal of the SMPTE ( Volume: 76, Issue: 6, June 1967)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Mechanical and Electronic Layout of a Color 16mm Scanner with Pneumatic Fast Pulldown",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J16747",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J16747",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J16747",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0361-4573",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_76_6/MIJR15Vol76No6.xml)",
      "source": "parsed",
      "updated": "2026-06-17T00:17:09.425Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "6",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "535–539",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1967-06-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
        "source": "parsed",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_76_6/MIJR15Vol76No6.xml)",
        "source": "parsed",
        "updated": "2026-06-17T00:17:09.425Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal papers default active",
        "source": "inferred",
        "updated": "2026-05-22T21:44:19.125Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "76",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J16747.xml)",
      "source": "parsed",
      "updated": "2026-05-22T21:44:19.125Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}