{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J14758",
  "document": {
    "abbrevTitle": "J SMPE",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "The quality of reproduction of sound in a theater must be good at all times, and sound outages must be kept to a minimum. This can be accomplished only by having the equipment checked carefully and periodically by engineers specially qualified and equipped for such work. Certain parts of sound equipment are subject to wear. The parts most likely to fail are carefully inspected for danger signs by the engineer on each of his visits. Other parts, critical in adjustment, are readjusted on each visit to maintain the quality of sound at the high standard set by the manufacturer and demanded by the public. RCA Photophone, Inc., has devised special appliances and tools to facilitate the adjustment of sound reproducing equipment. This paper describes the special test reel and methods used to maintain the sound quality at the required high standards.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "J. Mauran"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1932",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J14758",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J14758",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "Journal of the Society of Motion Picture Engineers ( Volume: 19, Issue: 3, September 1932)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Modern Tools and Methods used in Servicing Sound Equipment",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J14758",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J14758",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J14758",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0097-5834",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_19_3/MIJR15Vol19No3.xml)",
      "source": "parsed",
      "updated": "2026-06-17T00:17:09.425Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "3",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "260–271",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1932-09-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_19_3/MIJR15Vol19No3.xml)",
        "source": "parsed",
        "updated": "2026-06-17T00:17:09.425Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal papers default active",
        "source": "inferred",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "19",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J14758.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}