{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J11973",
  "document": {
    "abbrevTitle": "J SMPE",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "A motion picture film scanner, the first of the continuous type to be used for television transmissions, is described. The apparatus was put into operation in New York City in the summer of 1937 and has been in use since. In its preferred form the scanner projects the image of a continuously moving film onto the cathode of a dissector tube. Five images, representing different portions of the film in the gate, produced by five stationary lenses, are superimposed one on top of the other, while a rotating shutter with concentric slots permits only one lens at a time to produce an image. The scanning is accomplished partly by the uniform motion of the film and partly by the magnetic scanning of the electron image in the opposite direction. The pictures thus obtained are completely free from shading, cover a great range of contrast, are free from flicker, and are steady. The construction of the scanner is simple and inexpensive.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "Peter C. Goldmark"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1939",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J11973",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J11973",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "Journal of the Society of Motion Picture Engineers ( Volume: 33, Issue: 7, July 1939)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "A Continuous Type Television Film Scanner",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J11973",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J11973",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J11973",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0097-5834",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_33_7/MIJR15Vol33No7.xml)",
      "source": "parsed",
      "updated": "2026-06-16T18:14:32.753Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "7",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "18–25",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1939-07-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_33_7/MIJR15Vol33No7.xml)",
        "source": "parsed",
        "updated": "2026-06-16T18:14:32.753Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal papers default active",
        "source": "inferred",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "33",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11973.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}