{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-07-09T21:16:49.031Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J11446",
  "document": {
    "abbrevTitle": "SMPTE Mot. Imag. J",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "Multiple, closely similar, stadium-seating cinemas equipped with a variety of state-of-the-art sound systems from various manufacturers were thoroughly characterized for sound quality. All the auditoriums were acoustically similar and met all contemporary standards. Findings including acoustical issues remaining after the standard reverberation time, background noise level, and isolation, have been addressed. New or extended findings were made, particularly related to the effects of auditorium features such as stadium seating, regularly spaced rows of seats, the low wall(s) that separate the lead-in ramp area from the stairs up to seating, and backwall absorption. Traditional problems such as screen loss and reflections between the screen and horns were investigated, as well as sound system design elements. The principal findings involve a new method of mapping the coverage of the sound system, with individual response curves for both the long-term steady-state and the first arrival sound, mapped on a grid of typically ten points in the auditorium. Thus problems arising from directional effects in the loudspeaker output or screen modification of the output in coverage, and room acoustics, are well documented. Also included are subwoofer placement effects, the differences between compression drivers equipped with titanium and those with beryllium diaphragms, and others.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      {
        "affiliation": "The University of Southern California",
        "name": "Tomlinson Holman"
      }
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Object form (schema 2.3.0) migrated from string form via migrateAuthorsToObjectForm.js; bio/affiliation backfilled from _source/SMPTE/HIGHWIRE/ NLM <contrib-group>+<aff>+<bio>",
      "source": "parsed",
      "updated": "2026-06-23T00:04:25.562Z",
      "version": "authors-migrate-object-form@v1"
    },
    "contentType": "orig-research",
    "contentType$meta": {
      "confidence": "high",
      "note": "Cross-filled from SMPTE canonical repository import (smpte-canonical-audit/canonicalLibrary.*.json); previous value was a placeholder",
      "originalValue": "other",
      "source": "parsed",
      "updated": "2026-07-07T23:39:31.295Z",
      "version": "smpte-canonical-repo@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "2007",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J11446",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J11446",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "SMPTE Motion Imaging Journal ( Volume: 116, Issue: 5-6, 2007)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Cinema Electro-Acoustic Quality Redux",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J11446",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J11446",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J11446",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "electronic": "2160-2492",
      "electronic$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "print": "1545-0279",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08202015 BACKFILE JOURNAL FRESH/smptej_116_5-6/MIJR15Vol116No5-6.xml)",
      "source": "parsed",
      "updated": "2026-06-16T18:14:32.753Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "journalTitle": "SMPTE Motion Imaging Journal",
    "journalTitle$meta": {
      "confidence": "high",
      "note": "Era-accurate journal title from SMPTE canonical repository (periodical parent at time of publication) (smpte-canonical-audit/canonicalLibrary.*.json)",
      "originalValue": null,
      "source": "parsed",
      "updated": "2026-07-08T00:35:38.133Z",
      "version": "smpte-canonical-repo@v1"
    },
    "number": "5-6",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "220–233",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "2007-05-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Month corrected from SMPTE canonical repository (registry had Jan-1 placeholder) (smpte-canonical-audit/canonicalLibrary.*.json)",
      "originalValue": "2007-01-01",
      "source": "parsed",
      "updated": "2026-07-08T00:35:38.133Z",
      "version": "smpte-canonical-repo@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08202015 BACKFILE JOURNAL FRESH/smptej_116_5-6/MIJR15Vol116No5-6.xml)",
        "source": "parsed",
        "updated": "2026-06-16T18:14:32.753Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "references": {
      "bibliographic": [
        "orphan/10.5594-J11446/bibr1-10.5594_J11446",
        "orphan/10.5594-J11446/bibr2-10.5594_J11446",
        "orphan/10.5594-J11446/bibr3-10.5594_J11446",
        "orphan/10.5594-J11446/bibr4-10.5594_J11446",
        "orphan/10.5594-J11446/bibr5-10.5594_J11446",
        "orphan/10.5594-J11446/bibr6-10.5594_J11446",
        "orphan/10.5594-J11446/bibr7-10.5594_J11446",
        "orphan/10.5594-J11446/bibr8-10.5594_J11446",
        "orphan/10.5594-J11446/bibr9-10.5594_J11446",
        "orphan/10.5594-J11446/bibr10-10.5594_J11446"
      ],
      "bibliographic$meta": {
        "confidence": "medium",
        "note": "Extracted from NLM <ref-list> via extractSmpteJournalRefs.js (orphan-slug-mint)",
        "source": "parsed",
        "updated": "2026-07-06T18:21:02.558Z"
      }
    },
    "resolvedHref": "https://journal.smpte.org/periodicals/SMPTE%20Motion%20Imaging%20Journal/116/5-6/15/",
    "resolvedHref$meta": {
      "confidence": "high",
      "note": "Backfilled from url.validate report #resolvedHref",
      "originalValue": null,
      "source": "resolved",
      "updated": "2026-06-19T20:59:07.421Z"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal papers default active",
        "source": "inferred",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "116",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11446.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}