{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J11057",
  "document": {
    "abbrevTitle": "J SMPTE",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "The effect known as beam-landing error or “porthole” in vidicon cameras is eliminated through the use of a suitable coil configuration. The axial positions of the coils are chosen so that the beam electrons approach the target with only an axial component of velocity at all times. Exceptional signal uniformity independent of signal-electrode voltage and focus field strength is then obtained with a vidicon having a uniform photoconductor. A particular coil design and the results obtained with it are discussed.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "J. Castleberry",
      "B. H. Vine"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1959",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J11057",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J11057",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "Journal of the SMPTE ( Volume: 68, Issue: 4, April 1959)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from venue title, volume/issue and date",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "An Improved Vidicon Focusing-Deflecting Unit",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J11057",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J11057",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J11057",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0361-4573",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_68_4/MIJR15Vol68No4.xml)",
      "source": "parsed",
      "updated": "2026-06-16T18:14:32.753Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "4",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "226–229",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1959-04-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
        "source": "parsed",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_68_4/MIJR15Vol68No4.xml)",
        "source": "parsed",
        "updated": "2026-06-16T18:14:32.753Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal papers default active",
        "source": "inferred",
        "updated": "2026-05-22T20:40:11.684Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "68",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J11057.xml)",
      "source": "parsed",
      "updated": "2026-05-22T20:40:11.684Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}