{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J09093",
  "document": {
    "abstract": "More efficient methods are being used for sound transfer in the production of 8mm magnetic prints. From single 8mm recording using commercial magnetic projectors at sound speed, the operation has changed to the use of several single 8mm recorders running together. Equipment was developed for the simultaneous transfer of four tracks on 35mm striped color print film, perforated 5R-1500. When the four prints are exposed on a reduction printer with the four apertures staggered, the problem of designing a professional recorder becomes more complex. The design was intended not only to solve the problem of recording four staggered-sync soundtracks simultaneously, but to eliminate equipment, production and quality problems of the earlier systems. A rerecording system which overcomes these problems is described. In addition to the decreased film handling and increased production output, the system provides improved sound quality.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "Fred Schoelkopf",
      "Edgar Sghuller"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
        "source": "parsed",
        "updated": "2026-05-22T19:19:44.900Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1967",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
        "source": "parsed",
        "updated": "2026-05-22T19:19:44.900Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J09093",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J09093",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "Journal of the SMPTE ( Volume: 76, Issue: 10, October 1967)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from journal title, volume, issue and date",
      "source": "inferred",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Magnetic Sound Transfer onto Staggered-Sync Quad 8mm Prints",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J09093",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J09093",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J09093",
      "source": "inferred",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0361-4573",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
        "source": "parsed",
        "updated": "2026-05-22T19:19:44.900Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_76_10/MIJR15Vol76No10.xml)",
      "source": "parsed",
      "updated": "2026-06-16T16:11:59.617Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "10",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "1017–1021",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1967-10-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
        "source": "parsed",
        "updated": "2026-05-22T19:19:44.900Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_76_10/MIJR15Vol76No10.xml)",
        "source": "parsed",
        "updated": "2026-06-16T16:11:59.617Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal articles default active",
        "source": "inferred",
        "updated": "2026-05-22T19:19:44.900Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "76",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J09093.xml)",
      "source": "parsed",
      "updated": "2026-05-22T19:19:44.900Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}