{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J04855",
  "document": {
    "abbrevTitle": "J SMPTE",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "In storage-type television film pickup systems, usual either the light source is pulsed or else a mechanical shutter is used on the projector. This paper describes a third method, wherein the film is projected continuously, even during pulldown, on the photocathode of an image-orthicon tube. The image section of the tube, however, is keyed electronically so that it operates only during vertical blanking. Simple apparatus for the use with studio cameras is described.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "F. Cecil Grace"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1954",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J04855",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J04855",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "Journal of the Society of Motion Picture and Television Engineers ( Volume: 63, Issue: 3, September 1954)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from journal title, volume, issue and date",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Electronic Shutter in Television Film Pickup",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J04855",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J04855",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J04855",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0898-042X",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_63_3/MIJR15Vol63No3.xml)",
      "source": "parsed",
      "updated": "2026-06-16T16:11:59.617Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "3",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "88–89",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1954-09-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08182015 BACKFILE JOURNAL FRESH/smptej_63_3/MIJR15Vol63No3.xml)",
        "source": "parsed",
        "updated": "2026-06-16T16:11:59.617Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal articles default active",
        "source": "inferred",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "63",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J04855.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}