{
  "$schema": "/api/schemas/documents.schema.json",
  "apiVersion": "1.0.0",
  "generatedAt": "2026-06-17T23:49:39.838Z",
  "sourcePath": "src/main/data/docs",
  "docId": "10.5594-J03424",
  "document": {
    "abbrevTitle": "J SMPTE",
    "abbrevTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "abstract": "Perpendicular magnetic recording, in which the direction of magnetization is predominantly perpendicular to the plane of the tape or disk, is a relatively new technology that promises information densities significantly higher than those currently used. New recording media and heads are currently being developed and impressive results obtained. Head design and the proximity of the head to the recording surface remain factors of critical importance to high-density information storage, just as in conventional magnetic recording.",
    "abstract$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "articleType": "research-article",
    "articleType$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "authors": [
      "Michael P. Sharrock",
      "Daniel P. Stubbs"
    ],
    "authors$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "copyright": {
      "holder": "Society of Motion Picture and Television Engineers, Inc.",
      "holder$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "year": "1984",
      "year$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "copyright$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docId": "10.5594-J03424",
    "docId$meta": {
      "confidence": "high",
      "note": "Derived from DOI 10.5594/J03424",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docLabel": "SMPTE Journal ( Volume: 93, Issue: 12, December 1984)",
    "docLabel$meta": {
      "confidence": "medium",
      "note": "Composed from journal title, volume, issue and date",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docTitle": "Perpendicular Magnetic Recording Technology: A Review",
    "docTitle$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "docType": "Journal Article",
    "docType$meta": {
      "confidence": "high",
      "note": "NLM <article> — SMPTE journal paper",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "doi": "10.5594/J03424",
    "doi$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "href": "https://doi.org/10.5594/J03424",
    "href$meta": {
      "confidence": "high",
      "note": "Constructed from DOI 10.5594/J03424",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "issn": {
      "print": "0036-1682",
      "print$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "issn$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "journalAcronym": "MIJR",
    "journalAcronym$meta": {
      "confidence": "high",
      "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08202015 BACKFILE JOURNAL FRESH/smptej_93_12/MIJR15Vol93No12.xml)",
      "source": "parsed",
      "updated": "2026-06-16T00:32:03.060Z",
      "version": "smpte-journal-issue-xml@v1"
    },
    "number": "12",
    "number$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "pages": "1127–1133",
    "pages$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publicationDate": "1984-12-01",
    "publicationDate$meta": {
      "confidence": "high",
      "note": "Day absent in NLM source — padded to 01",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisher": "SMPTE",
    "publisher$meta": {
      "confidence": "high",
      "note": "Normalised to registry \"SMPTE\" convention from NLM publisher-name (The Society of Motion Picture and Television Engineers)",
      "source": "inferred",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "publisherLocation": {
      "city": "White Plains, NY",
      "city$meta": {
        "confidence": "high",
        "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
        "source": "parsed",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      },
      "country": "USA",
      "country$meta": {
        "confidence": "high",
        "note": "Parsed from journal_metadata XML (_source/SMPTE/APTARA/DL Project Files/08202015 BACKFILE JOURNAL FRESH/smptej_93_12/MIJR15Vol93No12.xml)",
        "source": "parsed",
        "updated": "2026-06-16T00:32:03.060Z",
        "version": "smpte-journal-issue-xml@v1"
      }
    },
    "publisherLocation$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    },
    "status": {
      "active": true,
      "active$meta": {
        "confidence": "medium",
        "note": "No explicit status in NLM source — journal articles default active",
        "source": "inferred",
        "updated": "2026-05-22T18:56:53.245Z",
        "version": "smpte-journal-article-nlm@v1"
      }
    },
    "volume": "93",
    "volume$meta": {
      "confidence": "high",
      "note": "Parsed from NLM article XML (_source/SMPTE/HIGHWIRE/Source Bak/smptej/10.5594_J03424.xml)",
      "source": "parsed",
      "updated": "2026-05-22T18:56:53.245Z",
      "version": "smpte-journal-article-nlm@v1"
    }
  }
}